xMAP INTELLIFLEX®
Technology you trust. Versatility you want.
The xMAP INTELLIFLEX® System is the only compact, flow-based, multiplex platform that combines the proven performance of xMAP® Technology with modern features to enhance performance, empower assay development innovation, and simplify your user experience. No other multiplex platform combines low- and high-plex capabilities, quick time to reliable results, and the ability to acquire data for two parameters per analyte simultaneously.
xMAP INTELLIFLEX® main features
Why choose xMAP INTELLIFLEX® System
Genomic & proteomics drug discovery
- Single nucleotide polymorphisms (SNPs)
- Expression analysis
- High-throughput compound screening
- Kinase selectivity screening of candidates
- Serological studies
- Multianalyte drug and drug metabolite profiling
- Toxicology & drug metabolism studies
- Drug target validation (receptor-ligand analysis)
Research assay applications
- Gene expression analysis
- Genotyping
- Protein expression analysis
- Animal-model serum analyte profiling
- Antibody epitope mapping
- Enzyme/substrate research
- Protein-protein interaction analysis
Systems
Product |
Registration Status |
Part Number |
---|---|---|
xMAP INTELLIFLEX® |
RUO |
INTELLIFLEX-RUO |
xMAP INTELLIFLEX® DR-SE |
RUO |
INTELLIFLEX-DRSE-RUO |
For research use only. Not for use in diagnostic procedures.
Reagents
Associated reagents for the xMAP INTELLIFLEX® system are
Product |
Registration status |
Part number |
---|---|---|
xMAP INTELLIFLEX® performance verification kit, 20 uses |
RUO |
IFX-PVER-K20 |
xMAP INTELLIFLEX® calibration kit, 20 uses |
RUO |
IFX-CAL-K20 |
xMAP® Sheath Fluid PLUS, 20 L |
RUO |
40-50021 |
xMAP® Sheath Concentrate PLUS, 1 L |
RUO |
40-50023 |
Accessories & Spare Parts
Product |
Part Number |
---|---|
Syringe Cylinder with Seal, 500 μL |
CN-0013-01 |
Sheath Filter with Quick Disconnect |
CN-0010-01 |
Sample Probe Needles |
CN-0221-01 |
Sample Probe height adjustment kit |
CN-0015-01 |
Power Cable, Country-Specific |
CN-PXXX-01* |
Preventative Maintenance (PM) kit, 6 months |
CN-0458-01 |
Off-Plate Reagent block |
CN-0514-01 |
Heater Block, 96-Well Microtiter Plates |
CN-0224-01 |
Heater Block, 384-Well Microtiter Plates |
CN-0223-01 |
*XXX is a country specific part number. For more information, contact Luminex Technical Support.
Technical Specifications
|
xMAP INTELLIFLEX® RUO |
xMAP INTELLIFLEX® DR-SE RUO |
---|---|---|
Performance |
||
Multiplexing Capability |
Up to 500 individual analytes per well |
Up to 500 individual analytes per well; Up to 2 parameters per analyte |
Typical Dynamic Range |
≥5.5 logs |
≥5.5 logs ≥4.5 logs (second reporter channel*) |
Plate Run Time |
96-well plate in ~20 min 384-well plate in ~75 min |
96-well plate in ~20 min 384-well plate in ~75 min |
Sensitivity |
Commercially available kits deliver sensitivity as low as sub-picogram level |
Commercially available kits deliver sensitivity as low as sub-picogram level |
General |
||
Physical Dimensions |
58.4 cm (23 in.) W x 61 cm (24 in.) D x 76.2 cm (30 in.) H |
58.4 cm (23 in.) W x 61 cm (24 in.) D x 76.2 cm (30 in.) H |
Weight |
54.4 kg (120 lbs) |
54.4 kg (120 lbs) |
Automation-Compatible Hardware |
Front eject only |
Front and side eject |
System Warm-Up |
30 min |
30 min |
Operating Temperature |
15–30°C (59–86°F) |
15–30°C (59–86°F) |
Operating System |
Microsoft Windows® 10 IoT Enterprise LTSC |
Microsoft Windows® 10 IoT Enterprise LTSC |
Barcode Reader |
For importing target values from the xMAP INTELLIFLEX® Calibration and Performance Verification Kits |
For importing target values from the xMAP INTELLIFLEX® Calibration and Performance Verification Kits |
Sheath Pressure |
8–13 psi |
8–13 psi |
Sample Injection Rate |
2 μL/sec |
2 μL/sec |
Sample Uptake Volume |
10–200 μL |
10–200 μL |
Optics |
||
Lasers |
1 Classification laser |
1 Classification laser |
Classification Laser Excitation |
638 nm |
638 nm |
Reporter Laser 1 (RP1) Excitation |
532 nm |
532 nm |
Reporter Laser 2 (RP2) Excitation |
N/A |
405 nm |
RP1 Detector |
565–585 nm |
565–585 nm |
RP2 Detector |
N/A |
421–441 nm |
Optional Software |
||
Electronic Records Compliance Module |
Yes |
Yes |
Automation Module |
Yes |
Yes |